daddypoy.blogg.se

Keyspan 19hs usb 2 serial xp driver
Keyspan 19hs usb 2 serial xp driver











keyspan 19hs usb 2 serial xp driver
  1. #Keyspan 19hs usb 2 serial xp driver drivers#
  2. #Keyspan 19hs usb 2 serial xp driver windows#

  • In XP, I went into the Add Hardware wizard, and scrolled down to the bottom to add hardware I pick from a list.
  • Downloaded SerialClient, the excellent app that seems to make this work.
  • #Keyspan 19hs usb 2 serial xp driver drivers#

    Installed the Keyspan drivers on my Mac (Leopard, 10.5.4).It turns out that I hadn't turned them on in VirtualBox, so I did that.

    #Keyspan 19hs usb 2 serial xp driver windows#

    Windows XP installed without a hitch, but it had no COM ports set up.Here's what I did just now to get my Keyspan USA-19HS USB-to-Serial adapter working in VirtualBox under Windows XP: For some of us, we not only need to run a Windows app, but that app requires a connection to a serial device. Upon startup, if the communication error persists, uninstall the Stamp Editor program, then reinstall the program from the CD-ROM.Sun's VirtualBox is a slick new virtualization alternative to VMWare Fusion, Parallels, and the like. Select the baud rate of 57600, then click Next. If the name doesn't match, click ▼ to open the drop down and pick the correct port, then continue to step m. If the name matches, continue to step m. Verify that the name in the drop down under "Serial Port" matches the name that you assigned earlier. Click on Baudrate, then press Properties to start the Baud Rate Wizard. Click WinPrint on the left side under "Print processor" and RAW on the right side under "Default data type." Both should be highlighted. Verify that Enable Bidirectional Support is checked. If COM10 was selected, it will say PTCOM10, etc.Į. If COM5 was selected for the Keyspan Adapter, then for the SC2000 it should say PTCOM5. Verify that a PTCOM port is selected and that Port Number is the same number that was selected for the Keyspan Adapter. Open the Printers and Faxes folders, then right click on the SC2000.ĭ. Close the Keyspan Serial Assistant by clicking the Red X in the upper right-hand corner.Ī. Click on Show ALL COM Assignments, then select a port between COM1 to COM10 from the available list.Į. If the port assignment for the adapter is between COM1 and COM10, go to step 7.ĭ. If the port assignment for the adapter is not between COM1 and COM10, go to step c. Verify the port assignment for the adapter is between COM1 and COM10. Click Start > Programs > Keyspan USB Serial Adapter > Keyspan Serial Assistant.ī. If you don't have this access, contact your Help Desk or Administrative Support.

    keyspan 19hs usb 2 serial xp driver

    To complete the next steps, you must have administrative rights/access to your computer. Change the port assignments on your computer. press Mode until "57600" is shown, then press Set to save.

    keyspan 19hs usb 2 serial xp driver

    If the "57600" is displayed, go to step 6.Ĭ. If there is a different number displayed, go to step c. Press Set to display the current Baud Rate. Press Mode four times to display "Baud Rate".ī. Verify that the green LED is illuminated.Ī.

    keyspan 19hs usb 2 serial xp driver

    Check that the USB cable is connected to the Keyspan device. That the serial cable is connected securely to the DB9 connector using the thumbscrews. Follow the serial cable to the USA-19HS Keyspan High-Speed USB-to-Serial Adapter. The part number is LN3043001 and can be purchase from. If the pins have been damaged a new serial cable will need to be purchased. Verify that the pins inside the cable aren't damaged, then plug it back in. Unplug the serial connector from the back of the SC2000. The USB cable is plugged into the USB port on the computer.ģ. A USB cable is connected to the USA-19HS Keyspan High-Speed USB-to-Serial Adapter. the D-shaped DB9 connector should be connected into the USA-19HS Keyspan High-Speed USB-to-Serial Adapter. If this part is plugged into the back of your computer, unplug it. The DIN connector, or "tail", on the short lead should be hanging loose as this is for Macintosh only. The round serial connector at the end of the long lead should be securely connected to the back of the StampCreator. At the rear of the SC2000, verify that the serial cable is plugged into the appropriate jack. Turn off the SC2000 for 5-to-10 seconds, then turn it back on to reset the electronics.Ģ. The normal cause for this error is that the SC2000 is either not connected properly or not turned on.ġ. Communication error indicates that the Stamp Editor program can't communicate with the SC2000.













    Keyspan 19hs usb 2 serial xp driver